Rare 2 you have a fan bearing going out.
Hp proliant dl360p gen8 fan replacement.
The server still shuts down if any single one of fans 5 8 are removed.
If this doesn t fix the problem then figure out what the fan is suppose to be cooling look to replacing that component.
Hot plug fan removal instructions.
However it does not shut down if a single fan from slots 1 4 is removed.
1 something is overheating driving your fan to max.
Common best to just order a replacement fan replace it.
Cost you a few dollars.
S union new replacement cpu cooling fan for hp proliant dl360 g8 dl360e g8 dl360p g8 fan module 654752 002 654752 003 732136 001 697183 002 697183 003 gfm0412ss 4 9 out of 5 stars 14 16 99.
Fans tend to be loud for two primary reasons.
Yeechun replacement new cpu cooling fan compatible with hp proliant dl360 g8 dl360e g8 dl360p g8 fan module 654752 002 654752 003 732136 001 697183 002 697183 003 gfm0412ss 5 0 out of 5 stars 2 15 99.
I also tried adding all fans 1 through 8.
Hot plug fan module removal instructions.
To view a video demonstrating the procedure for removing the hot plug fan module click here to view the hpe services media library and then select servers proliant dl servers and hpe proliant dl360p gen8 server and then click on remove replace on the new window select hot plug fan module from the menu on the upper left hand side of the screen.
Hp proliant dl360p gen8 server maintenance and service guide abstract this guide describes identification and maintenance procedures diagnostic tools specifications and requirements for hardware components and software.
Dl360p gen8 fans noisy 94 speed after firmware update ok i have fixed the issue by downgrading the p420i driver to v7 02now the leds are back on and the fans are back to 19 and the server isn t complaining about non hp disks.